00353 1 465 9010   00353 1 465 9011
Follow Us on:
M75

HT ITALIA M75 LAN tester

M75 is an innovative multifunction installation tester which joins together DMM, Safety Tester and LAN checker features inside a compact and ergonomic user-friendly structure and with a extremely reduced weight (800g only!). The DMM is a professional instrument with TRMS measurement of AC/DC voltage, AC Current (through external clamp), Resistance and Frequency. Additional features are MAX/MIN/AVG function, HOLD function and PEAK detection with Response Time of 1ms, useful for surge currents detection.
The multifunction installation tester features allow to perform test on electrical plants according to VDE0413. Measures of Continuity, Insulation, Global Earth value (also with 0.1 resolution), RCDs test, phase sequence indication and phase coincidence (using only one Test Lead even just touching even insulated cables or two Test Leads) will be easily performed thanks to this new extremely compact instrument. An innovative function (AUTOTEST) automatically performs main safety checks in the plant (Earth Resistance measurement, RCD Test, Insulation Test) just connecting the instrument to a socket and pressing the GO button. The instrument will give you a final response (OK or NOT OK) about the safety of the plant under test.

Product Description

tech_spec

 

 

Function
  • Continuity test of protective conductors with 200mA
  • Insulation Resistance measurement with 500VDC
  • Trip-out time of RCDs type A, AC Standard
  • Selectable test current; 30mA, 30x5mA, 100mA, 300mA
  • RCD Ramp test
  • Global Earth Resistance without RCD tripping
  • Global Earth Resistance with 0.1Ohm resolution
  • Phase sequence indication at 1 or 2 wires
  • Phase coincidence indication at 1 or 2 wire
  • Automatic test of global earth resistance + RDC test + Insulation test
  • Wire mapping test on LAN cables with RJ45 connector
  • DC Voltage
  • AC TRMS Voltage
  • AC TRMS Current with External Clamp
  • AC TRMS Leakage current with external clamp (optional)
  • Resistance
  • Continuity test with buzzer
  • Frequency with test leads
  • Frequency with external clamp
  • MIN/MAX/AVG functions
  • PEAK function with response time 1ms
  • HOLD function
  • Auto Power OFF
STANDARD
  • KIT0075 : Set 2 cables with leads  + 2 alligator clips
  • C2075 : Cable 2 wires with Shuko plug
  • CH1 : Remote unit #1
  • CH2 : Remote unit #2
  • Patch cable RJ45, FTP, 20cm, 3 pcs
  • HT4003 : Rigid clamp 400A AC, diameter 30mm
  • BORSA75 : Carrying bag
  • ISO9000 calibration certificate
  • User manual on CD-ROM
  • Quick reference guide
OPTIONAL
  • HT96U : Rigid clamp 1-100-1000A AC, diameter 54mm
  • HT4004N : Transducer clamp 10-100A DC
  • REM3 : Remote unit #3
  • REM4 : Remote unit #4
  • REM5 : Remote unit #5
  • REM6 : Remote unit #6
  • REM7 : Remote unit #7
  • REM8 : Remote unit #8
  • REM38 : Remote units from #3 to #8
  • NOCANBA : Adapter Hypertac female/Banana males
Standards

EMC 2004/108/CE Directive
CE MARK
EN 61008
IEC/EN61557-1
IEC/EN61557-2
IEC/EN61557-3
IEC/EN61557-4
IEC/EN61557-6
IEC/EN61557-7
LVD 2006/95/CE Directive