<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>RFE &#187; Products</title>
	<atom:link href="http://rfe.ie/shop/feed/?product_cat=blowerdoor-airtightness-testing-equipment-retrotec" rel="self" type="application/rss+xml" />
	<link>http://rfe.ie</link>
	<description>Reg Farrell Engineering Ltd.</description>
	<lastBuildDate>Tue, 10 Oct 2017 13:41:34 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=4.2.2</generator>
	<item>
		<title>351 European DucTester</title>
		<link>http://rfe.ie/product/351-european-ductester/</link>
		<comments>http://rfe.ie/product/351-european-ductester/#comments</comments>
		<pubDate>Wed, 14 Jan 2015 11:30:10 +0000</pubDate>
		<dc:creator><![CDATA[rfe]]></dc:creator>
		
		<guid isPermaLink="false">http://rfe.ie/?post_type=product&#038;p=4566</guid>
		<description><![CDATA[<p>The Model 351 is Europe’s smarter brother to the Model 341. The 351 has twice as many ranges that will measure flows down to 0.6 liters per second but will also go up to 350 liters per second to test houses by adding the optional frame package.  Over 30 years of airtightness technology and design expertise have gone into making this the most flexible but also the most reasonably priced DucTester for residential and small commercial duct tests at 80, 160 and 250 Pascals.</p>
<p>Super lightweight, easy operation, great quick guides make this the best choice for testing European ducts.  Runs on any voltage from 100 to 280 Volts or for 3 hours on an optional 48 Volt Lithium Ion battery pack that weighs 3 kg.</p>
<p><a href="http://rfe.ie/wp-content/uploads/2015/01/351-European-DucTester-_-Retrotec.pdf"><img class="alignleft wp-image-7583 " src="http://rfe.ie/wp-content/uploads/2015/12/tech_spec-300x50.gif" alt="tech_spec-300x50" width="210" height="35" /></a></p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a rel="nofollow" href="http://rfe.ie/product/351-european-ductester/">351 European DucTester</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p>The post <a rel="nofollow" href="http://rfe.ie/product/351-european-ductester/">351 European DucTester</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://rfe.ie/product/351-european-ductester/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>5101F Classic Fire</title>
		<link>http://rfe.ie/product/5101f-classic-fire/</link>
		<comments>http://rfe.ie/product/5101f-classic-fire/#comments</comments>
		<pubDate>Wed, 14 Jan 2015 14:30:01 +0000</pubDate>
		<dc:creator><![CDATA[rfe]]></dc:creator>
		
		<guid isPermaLink="false">http://rfe.ie/?post_type=product&#038;p=4583</guid>
		<description><![CDATA[<p>Definitely the most for the least. You cannot get more Enclosure Integrity value than the 5101F offers. Everything you need and nothing you don’t for entry level testing.</p>
<p>Test for hold times in flooded volumes up to 35,000 cu ft (1000 m<sup>3</sup>) for Inert agents and 70,000 cu ft (2000 m<sup>3</sup>) for halocarbon chemical agents.</p>
<p>Testing pressure relief vents will require more power however. This system will test the venting for a volume up to a maximum of 9,000 cu ft (250 m<sup>3</sup>) for Inert agents although vents up to 6 sq ft (0.6 m<sup>2</sup>) can be measured individually.</p>
<p>Request literature on all of Retrotec systems to determine the size of enclosures that can be tested with each system.</p>
<p>All Retrotec systems include tech support from Retrotec who originated the idea of Enclosure Integrity testing in 1984. They promoted it within NFPA and in 1986 wrote the first Enclosure Integrity standard. Retrotec has been the lead researcher for enclosure testing ever since.  Every major clean agent system manufacturer worldwide relies on Retrotec’s expertise for both hold time and peak pressure predictions.</p>
<p><a href="http://rfe.ie/wp-content/uploads/2015/01/5101F-Classic-Fire-_-Retrotec.pdf"><img class="alignleft wp-image-7583 " src="http://rfe.ie/wp-content/uploads/2015/12/tech_spec-300x50.gif" alt="tech_spec-300x50" width="210" height="35" /></a></p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a rel="nofollow" href="http://rfe.ie/product/5101f-classic-fire/">5101F Classic Fire</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p>The post <a rel="nofollow" href="http://rfe.ie/product/5101f-classic-fire/">5101F Classic Fire</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://rfe.ie/product/5101f-classic-fire/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>5121 Hard Panel Pro</title>
		<link>http://rfe.ie/product/5121-hard-panel-pro/</link>
		<comments>http://rfe.ie/product/5121-hard-panel-pro/#comments</comments>
		<pubDate>Wed, 27 Jan 2016 16:10:44 +0000</pubDate>
		<dc:creator><![CDATA[rfe]]></dc:creator>
		
		<guid isPermaLink="false">http://rfe.ie/?post_type=product&#038;p=7823</guid>
		<description><![CDATA[<p>This most professional looking system is quickest to set up with no cloth flapping around.  Install and re-pack up in seconds and look good doing it.</p>
<p>One big reason for the popularity of the 5000 series fans is you don’t have to attend a training course to learn how to use it. Just read the Quick Guide, maybe watch the video and in 15 minutes, you’ve performed your first test. Another reason, this performance leader gets 6700 CFM (11,383 m3/h) out of its ¾ hp motor which is more than any competitive unit because if its efficient size and sophisticated on board speed control. Adjust the fan speed manually using the control knob, or the TV-remote style control on the gauge, or Set to Pressure which works like Cruise Control on your car or fully automatically with the free FanTestic PC software package.</p>
<p><a href="http://rfe.ie/wp-content/uploads/2016/01/5121-Hard-Panel-Pro-_-Retrotec.pdf"><img class="alignleft wp-image-7583 " src="http://rfe.ie/wp-content/uploads/2015/12/tech_spec-300x50.gif" alt="tech_spec-300x50" width="210" height="35" /></a></p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a rel="nofollow" href="http://rfe.ie/product/5121-hard-panel-pro/">5121 Hard Panel Pro</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p>The post <a rel="nofollow" href="http://rfe.ie/product/5121-hard-panel-pro/">5121 Hard Panel Pro</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://rfe.ie/product/5121-hard-panel-pro/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>5211 Double Classic</title>
		<link>http://rfe.ie/product/5211-double-classic/</link>
		<comments>http://rfe.ie/product/5211-double-classic/#comments</comments>
		<pubDate>Wed, 27 Jan 2016 15:56:58 +0000</pubDate>
		<dc:creator><![CDATA[rfe]]></dc:creator>
		
		<guid isPermaLink="false">http://rfe.ie/?post_type=product&#038;p=7820</guid>
		<description><![CDATA[<p>This complete Blower Door Air Leakage Test system, with two fans that you can run simultaneously, has everything you need to easily test larger or leakier buildings. With a ¾ horsepower motor, the included 2 x Model 5000 Calibrated Fans produce up to 13,400 CFM, making it more than capable of measuring air leakage in both small to medium sized commercial or multi-family buildings.</p>
<p>The two 5000 fans with Large Cloth Panel performs fully automatic testing using the gauge, a laptop and the provided FanTestic software. Alternatively, simply key the desired test pressure into the gauge and read Air Changes or leakage per unit area in real time directly from the touchscreen gauge; a unique Retrotec feature. The gauge also offers an onboard "Set-and-Forget" control of enclosure pressure. All you need to do is choose your desired pressure, and then let the gauge do the rest.  As you seal the leaks in your enclosure and the leakage rate decreases, the system automatically and instantly readjusts the fan to keep the enclosure at the correct pressure.</p>
<p>Software provided with the DM32 gauge provides automatic data logging, and remote gauge control from a laptop. With our new 5 year calibration schedule on the DM32, you will have the peace of mind knowing that yearly calibrations are a thing of the past.</p>
<p><a href="http://rfe.ie/wp-content/uploads/2016/01/5211-Double-Classic-_-Retrotec.pdf"><img class="alignleft wp-image-7583 " src="http://rfe.ie/wp-content/uploads/2015/12/tech_spec-300x50.gif" alt="tech_spec-300x50" width="210" height="35" /></a></p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a rel="nofollow" href="http://rfe.ie/product/5211-double-classic/">5211 Double Classic</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p>The post <a rel="nofollow" href="http://rfe.ie/product/5211-double-classic/">5211 Double Classic</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://rfe.ie/product/5211-double-classic/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>5311 Triple Classic</title>
		<link>http://rfe.ie/product/5311-triple-classic/</link>
		<comments>http://rfe.ie/product/5311-triple-classic/#comments</comments>
		<pubDate>Tue, 13 Jan 2015 14:20:54 +0000</pubDate>
		<dc:creator><![CDATA[rfe]]></dc:creator>
		
		<guid isPermaLink="false">http://rfe.ie/?post_type=product&#038;p=4545</guid>
		<description><![CDATA[<p>This System has three Model 5000 Calibrated Fans in one Large Cloth panel door frame system. This is the most economical way to blow large quantities of air to test Commercial, Multi-Family or High Rise buildings.</p>
<p>The 3 included DM32 digital gauges are more advanced than any competitive gauge and ideal when running the 5311 manually or fully automatically using a computer and the optional Multi-FanTestic Software.  The DM32 also allows tests when fans are separated by large distances.  An available upgrade is the DM32 WiFi, which adds the wireless feature that generally is not needed for large set ups since wired connections are more dependable but works very well when distances are line of sight.</p>
<p>You may also run automatic data logging from multiple fans, and remote gauge control from a laptop. With our new 5 year recommended calibration interval on the DM32, you will have the peace of mind knowing that yearly calibrations are a thing of the past.</p>
<p>Calibrated range configurations allow one fan to test a wide range of enclosures, from super leaky to super tight. This high output fan includes 6 flow ranges to provide accurate results over the widest range of enclosure volumes. All Retrotec fans are made with extremely durable space-age plastic foam, which makes them both lightweight and tough. They are also easily reversible: to switch from pressurizing to depressurizing your enclosure, simply flip the fan around in its panel.</p>
<p>Run only a single Ethernet cable from test area to the laptop to control your test.</p>
<p><a href="http://rfe.ie/wp-content/uploads/2015/01/5311-Triple-Classic-_-Retrotec.pdf"><img class="alignleft wp-image-7583 " src="http://rfe.ie/wp-content/uploads/2015/12/tech_spec-300x50.gif" alt="tech_spec-300x50" width="210" height="35" /></a></p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a rel="nofollow" href="http://rfe.ie/product/5311-triple-classic/">5311 Triple Classic</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p>The post <a rel="nofollow" href="http://rfe.ie/product/5311-triple-classic/">5311 Triple Classic</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://rfe.ie/product/5311-triple-classic/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>6112F Hi-Power Fire</title>
		<link>http://rfe.ie/product/6112f-hi-power-fire/</link>
		<comments>http://rfe.ie/product/6112f-hi-power-fire/#comments</comments>
		<pubDate>Wed, 14 Jan 2015 15:02:45 +0000</pubDate>
		<dc:creator><![CDATA[rfe]]></dc:creator>
		
		<guid isPermaLink="false">http://rfe.ie/?post_type=product&#038;p=4586</guid>
		<description><![CDATA[<p>To see if dampers really have the vent area they claim to have, they need to be tested and this model does that really well. It not only has lots of flow but can create 100s of Pa to see at what point the Pressure Relief Vents actually open. Then it will test the vent path to ensure the peak pressure evaluation complies with the standard.  Sufficient power also to test larger enclosures and an ideal place to start since it can be easily upgraded to the full feature 3212F when you want to measure the lower leak which often is the only way to pass many enclosures.</p>
<p>Test for hold times in flooded volumes up to 51,000 cu ft (1000 m3) for Inert agents and 70,000 cu ft (2000 m3) for halocarbon chemical agents.</p>
<p>Testing pressure relief vents will require more power however. This system will test the venting for a volume up to a maximum of 12,000 cu ft (330 m3) for Inert agents although vents up to 8 sq ft (0.8 m2) can be measured individually.</p>
<p>Request literature on all of Retrotec systems to determine the size of enclosures that can be tested with each system.</p>
<p>All Retrotec systems include tech support from Retrotec who originated the idea of Enclosure Integrity testing in 1984. They promoted it within NFPA and in 1986 wrote the first Enclosure Integrity standard. Retrotec has been the lead researcher for enclosure testing ever since.  Every major clean agent system manufacturer worldwide relies on Retrotec’s expertise for both hold time and peak pressure predictions.</p>
<p><a href="http://rfe.ie/wp-content/uploads/2015/01/6112F-Hi-Power-Fire-_-Retrotec.pdf"><img class="alignleft wp-image-7583 " src="http://rfe.ie/wp-content/uploads/2015/12/tech_spec-300x50.gif" alt="tech_spec-300x50" width="210" height="35" /></a></p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a rel="nofollow" href="http://rfe.ie/product/6112f-hi-power-fire/">6112F Hi-Power Fire</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p>The post <a rel="nofollow" href="http://rfe.ie/product/6112f-hi-power-fire/">6112F Hi-Power Fire</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://rfe.ie/product/6112f-hi-power-fire/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>6122F Pro Fire</title>
		<link>http://rfe.ie/product/6122f-pro-fire/</link>
		<comments>http://rfe.ie/product/6122f-pro-fire/#comments</comments>
		<pubDate>Wed, 14 Jan 2015 15:44:17 +0000</pubDate>
		<dc:creator><![CDATA[rfe]]></dc:creator>
		
		<guid isPermaLink="false">http://rfe.ie/?post_type=product&#038;p=4590</guid>
		<description><![CDATA[<p>Power and Pro look and feel is the choice of top clean agent installing companies. The panel system not only sets up super-fast but looks good when during the test. You can easily open it up to gain access across the test door.</p>
<p>Test for hold times in flooded volumes up to 51,000 cu ft (1000 m3) for Inert agents and 70,000 cu ft (2000 m3) for halocarbon chemical agents.</p>
<p>Testing pressure relief vents will require more power however. This system will test the venting for a volume up to a maximum of 12,000 cu ft (330 m3) for Inert agents although vents up to 8 sq ft (0.8 m2) can be measured individually.</p>
<p>Request literature on all of Retrotec systems to determine the size of enclosures that can be tested with each system.</p>
<p>All Retrotec systems include tech support from Retrotec who originated the idea of Enclosure Integrity testing in 1984. They promoted it within NFPA and in 1986 wrote the first Enclosure Integrity standard. Retrotec has been the lead researcher for enclosure testing ever since.  Every major clean agent system manufacturer worldwide relies on Retrotec’s expertise for both hold time and peak pressure predictions.</p>
<p><a href="http://rfe.ie/wp-content/uploads/2015/01/6122F-Pro-Fire-_-Retrotec.pdf"><img class="alignleft wp-image-7583 " src="http://rfe.ie/wp-content/uploads/2015/12/tech_spec-300x50.gif" alt="tech_spec-300x50" width="210" height="35" /></a></p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a rel="nofollow" href="http://rfe.ie/product/6122f-pro-fire/">6122F Pro Fire</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p>The post <a rel="nofollow" href="http://rfe.ie/product/6122f-pro-fire/">6122F Pro Fire</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://rfe.ie/product/6122f-pro-fire/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Case for 1000 or 3000 Fan</title>
		<link>http://rfe.ie/product/retrotec-case-for-1000-or-3000-fan/</link>
		<comments>http://rfe.ie/product/retrotec-case-for-1000-or-3000-fan/#comments</comments>
		<pubDate>Thu, 15 Jan 2015 11:07:22 +0000</pubDate>
		<dc:creator><![CDATA[rfe]]></dc:creator>
		
		<guid isPermaLink="false">http://rfe.ie/?post_type=product&#038;p=4606</guid>
		<description><![CDATA[<div class="field field-name-field-product-introduction field-type-text-long field-label-hidden">
<div class="field-items">
<div class="field-item even">
<p>The Hard-sided Fan Case is custom designed to hold Retrotec fans (Model 1000 or 3000). This hard sided case fits the fan securely and closes with Velcro straps which double as handles. The hard top and convenient height also make the case usable as a jobsite table for laptops and gauges.</p>
<p>The Fan case protects the calibrated fan in transit, and keeps it clean while in storage.</p>
</div>
</div>
</div>
<div class="field field-name-field-product-features field-type-text-long field-label-above">
<div class="field-label">Features<span class="colon">: </span></div>
<div class="field-items">
<div class="field-item even">
<ul>
<li>Sturdy hard-sided construction</li>
<li>Hard top makes the case into a table top</li>
<li>Rugged, long wearing but lightweight cordura material</li>
</ul>
</div>
</div>
</div>
<p>The post <a rel="nofollow" href="http://rfe.ie/product/retrotec-case-for-1000-or-3000-fan/">Case for 1000 or 3000 Fan</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></description>
				<content:encoded><![CDATA[<div></div>
<p>The post <a rel="nofollow" href="http://rfe.ie/product/retrotec-case-for-1000-or-3000-fan/">Case for 1000 or 3000 Fan</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://rfe.ie/product/retrotec-case-for-1000-or-3000-fan/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Cloth for Large Frame Triple Fans</title>
		<link>http://rfe.ie/product/cloth-for-large-frame-triple-fans/</link>
		<comments>http://rfe.ie/product/cloth-for-large-frame-triple-fans/#comments</comments>
		<pubDate>Thu, 15 Jan 2015 15:13:23 +0000</pubDate>
		<dc:creator><![CDATA[rfe]]></dc:creator>
		
		<guid isPermaLink="false">http://rfe.ie/?post_type=product&#038;p=4645</guid>
		<description><![CDATA[<p>With the versatile cloth door panel, you can adapt your blower door system to test with a variety of larger door sizes. Included with Retrotec's Blower Door Systems, this door panel allows for maximum adaptability. The durable cloth panel fits across an easy-to-assemble and highly adjustable frame, allowing for maximum air tightness in your blower door setup. This cloth panel is designed for three fans on the door.</p>
<p>The cloth door panel comes in a rigid gun-style case for easy portability. When your air leakage test is complete, simply unclip and disassemble the frame, then roll up the cloth panel and you're on your way!</p>
<p><a href="http://rfe.ie/wp-content/uploads/2015/01/Cloth-Panel-for-Large-Frame-–Triple-Fan-_-Retrotec.pdf"><img class="alignleft wp-image-7583 " src="http://rfe.ie/wp-content/uploads/2015/12/tech_spec-300x50.gif" alt="tech_spec-300x50" width="210" height="35" /></a></p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a rel="nofollow" href="http://rfe.ie/product/cloth-for-large-frame-triple-fans/">Cloth for Large Frame Triple Fans</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p>The post <a rel="nofollow" href="http://rfe.ie/product/cloth-for-large-frame-triple-fans/">Cloth for Large Frame Triple Fans</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://rfe.ie/product/cloth-for-large-frame-triple-fans/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Cloth for Regular Frame Single 200 or 300 Fan</title>
		<link>http://rfe.ie/product/cloth-for-regular-frame-single-200-or-300-fan/</link>
		<comments>http://rfe.ie/product/cloth-for-regular-frame-single-200-or-300-fan/#comments</comments>
		<pubDate>Thu, 15 Jan 2015 14:52:59 +0000</pubDate>
		<dc:creator><![CDATA[rfe]]></dc:creator>
		
		<guid isPermaLink="false">http://rfe.ie/?post_type=product&#038;p=4636</guid>
		<description><![CDATA[<p>Retrotec’s cloth panel is the most economical choice for residential testing.  With the versatile cloth door panel, you can adapt your blower door system to test with a variety of door sizes. Included with Retrotec's Blower Door Systems, this door panel allows for maximum adaptability.  The durable cloth panel fits across an easy-to-assemble and highly adjustable frame, allowing for maximum air tightness in your blower door setup.</p>
<p>The cloth door panel comes in a rigid gun-style case for easy portability. When your air leakage test is complete, simply un clip and disassemble the frame, then roll up the cloth panel and you're on your way!</p>
<p><a href="http://rfe.ie/wp-content/uploads/2015/01/Cloth-Panel-for-Regular-Frame-–-Single-200_300-Fan-_-Retrotec.pdf"><img class="alignleft wp-image-7583 " src="http://rfe.ie/wp-content/uploads/2015/12/tech_spec-300x50.gif" alt="tech_spec-300x50" width="210" height="35" /></a></p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a rel="nofollow" href="http://rfe.ie/product/cloth-for-regular-frame-single-200-or-300-fan/">Cloth for Regular Frame Single 200 or 300 Fan</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></description>
				<content:encoded><![CDATA[<p>The post <a rel="nofollow" href="http://rfe.ie/product/cloth-for-regular-frame-single-200-or-300-fan/">Cloth for Regular Frame Single 200 or 300 Fan</a> appeared first on <a rel="nofollow" href="http://rfe.ie">RFE</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://rfe.ie/product/cloth-for-regular-frame-single-200-or-300-fan/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
